Skip to content

Cambridge IGCSE Biology · 0610 · Topic 5

Enzymes

Revision notes for topic 5 of the Cambridge IGCSE Biology syllabus, covering Enzymes, How an enzyme works, and specificity, Temperature and enzyme activity, pH and enzyme activity, Control experiments, and changing one variable at a time, Measuring and recording, Means, and when to leave a reading out, Choosing scales, plotting points and drawing the line, Reading values from a graph, and describing its shape, Errors, anomalies and improvements, Anomalous results, Enzyme activity against temperature and pH. Read the notes, then try the exam-style questions.

Revision notes

5.1

Enzymes

Describe enzymes as biological catalysts and explain the effects of temperature and pH.

Key points

  • A CATALYST increases the rate of a reaction and is NOT CHANGED by it.
  • ENZYMES are PROTEINS involved in all metabolic reactions, acting as biological catalysts.
  • They are essential because they give a reaction rate fast enough to sustain life.
  • The ACTIVE SITE is COMPLEMENTARY in shape to the substrate; products are then formed.
  • Investigate the effect of temperature and pH, with reference to OPTIMUM temperature and DENATURATION.
  • SUPPLEMENT: explain enzyme action using active site, ENZYME–SUBSTRATE COMPLEX, substrate and product.
  • SUPPLEMENT: specificity comes from the complementary shape and FIT of the active site with the substrate.
  • SUPPLEMENT — temperature: explain in terms of KINETIC ENERGY, shape and fit, FREQUENCY OF EFFECTIVE COLLISIONS, and denaturation.
  • SUPPLEMENT — pH: explain in terms of shape and fit, and denaturation.

Diagram

Enzymes are specific because the substrate must fit the active site.
Enzymes are specific because the substrate must fit the active site.
FactorBelow optimumAt optimumAbove optimum
Temperatureslow: few collisionsfastestDENATURES: active site changes shape
pHslowfastestDENATURES
Factors affecting enzyme activity

Worked example

4 marks

Explain why the rate of an enzyme reaction rises to an optimum temperature and then falls sharply.

Answer with Premium
Examiner's tip and common mistake · PremiumUnlock
5.1.1

How an enzyme works, and specificity

Explain enzyme action in terms of the active site and the enzyme-substrate complex, and explain specificity.

Key points

  • An ENZYME is a PROTEIN that works as a BIOLOGICAL CATALYST: it increases the rate of a reaction and is NOT USED UP or changed by it.
  • Enzymes are essential because they make reactions happen fast enough at body temperature to sustain life.
  • SUPPLEMENT: the SUBSTRATE binds to the ACTIVE SITE to form an ENZYME-SUBSTRATE COMPLEX; the reaction occurs, and the PRODUCTS leave, freeing the active site to be used again.
  • SUPPLEMENT: SPECIFICITY comes from the active site being COMPLEMENTARY IN SHAPE to the substrate, so that only that substrate fits.
  • One enzyme therefore catalyses one reaction: amylase breaks down starch and will not touch protein, however much protein is present.
  • Because one enzyme molecule can be reused again and again, a very small amount of enzyme can convert a large amount of substrate.
  • Raising the SUBSTRATE concentration increases the rate until every active site is occupied; after that the rate levels off, because adding more substrate cannot speed up enzymes that are already working.
  • Raising the ENZYME concentration then increases the rate again, because there are more active sites available.

Worked example

4 marks

Explain why amylase breaks down starch but has no effect on protein, and explain why the rate of an enzyme reaction levels off as the substrate concentration keeps rising.

Answer with Premium
Examiner's tip · PremiumUnlock
5.1.2

Temperature and enzyme activity

Explain the effect of temperature on enzyme activity using the required terms.

Key points

  • The rate RISES to an OPTIMUM TEMPERATURE and then falls STEEPLY. The curve is not symmetrical.
  • SUPPLEMENT: below the optimum, the explanation is in terms of KINETIC ENERGY — the molecules move faster, so there is a greater FREQUENCY OF EFFECTIVE COLLISIONS between enzyme and substrate, and more complexes form each second.
  • SUPPLEMENT: above the optimum, the heat changes the SHAPE of the enzyme, so the active site no longer FITS the substrate: the enzyme is DENATURED.
  • DENATURATION is PERMANENT. Cooling the enzyme down again does not restore the activity, which is why the fall is steeper than the rise.
  • Say DENATURED, never 'killed'. An enzyme is a molecule, not an organism, and 'killed' is marked wrong.
  • At LOW temperatures the enzyme is NOT denatured, only slow: warming it restores the activity completely. That is the difference examiners test.
  • The optimum is a property of the enzyme, not a universal figure: human enzymes work best near body temperature, but enzymes from other organisms have other optima.
  • In an investigation, BOTH solutions must reach the temperature of the water bath BEFORE mixing, or the reaction begins at the wrong temperature.

Worked example

4 marks

The rate at which an enzyme broke down its substrate rose from 1.2 to 5.4 cm cubed per minute between 10 and 40 degrees C, then fell to 0.6 cm cubed per minute at 60 degrees C. Explain the rise and the fall, and state what would happen if the sample at 60 degrees C were cooled back to 40 degrees C.

Answer with Premium
Examiner's tip · PremiumUnlock
5.1.3

pH and enzyme activity

Explain the effect of pH on enzyme activity and relate each digestive enzyme to the pH where it works.

Key points

  • Each enzyme has an OPTIMUM pH at which its rate is highest, and the rate falls away on BOTH sides of it.
  • SUPPLEMENT: the explanation is in terms of SHAPE AND FIT and DENATURATION — a pH away from the optimum changes the shape of the active site, so the substrate no longer fits.
  • A pH far from the optimum DENATURES the enzyme permanently; a small change away from it only slows the enzyme, and the rate recovers when the pH is restored.
  • PEPSIN, the protease of the stomach, has an optimum of about pH 2, which is why the stomach produces HYDROCHLORIC ACID.
  • The enzymes of the SMALL INTESTINE work best in slightly ALKALINE conditions, around pH 7 to 8, which is why BILE is needed to neutralise the acid arriving from the stomach.
  • SALIVARY AMYLASE works around pH 7 and stops working when the food reaches the acid of the stomach.
  • In an investigation, pH is fixed with BUFFER SOLUTIONS, with the same volume of buffer in every tube, and the temperature held constant throughout.
  • pH is not a temperature effect: an enzyme at the wrong pH is denatured by the change in shape, not by heat, so warming it will not help.

Worked example

4 marks

Explain why pepsin stops working when it passes from the stomach into the duodenum, and describe how a student would control pH in an investigation into its effect on an enzyme.

Answer with Premium
Examiner's tip · PremiumUnlock
P1.2

Control experiments, and changing one variable at a time

Distinguish a control variable from a control experiment, and explain what a control experiment shows.

Key points

  • A CONTROL VARIABLE is a quantity held constant. A CONTROL EXPERIMENT is a whole parallel run set up with the independent variable ABSENT.
  • The control experiment shows that the effect you measured was caused by the thing you were investigating and not by the apparatus, the solvent or the procedure.
  • Standard 0610 controls: BOILED (dead) seeds beside germinating seeds; a tube of BOILED enzyme beside the active enzyme; a DESTARCHED leaf left in the dark; dialysis tubing filled with WATER instead of starch solution.
  • An EMPTY tube is usually not a valid control: it does not control for the presence of the material itself, only for the apparatus.
  • Change only ONE variable at a time. Using a different enzyme concentration at each temperature means no conclusion can be drawn about temperature at all.
  • A CONFOUNDING variable changes alongside the independent variable without being noticed — a lamp moved closer also WARMS the water, so a faster rate may be temperature, not light.
  • Where a confounding variable cannot be removed, it must be blocked: a heat shield or a water bath between the lamp and the tube, with the temperature recorded to prove it stayed constant.

Worked example

3 marks

In an investigation into the effect of temperature on amylase activity, a student used a different concentration of amylase at each temperature. Explain why no valid conclusion can be drawn, and state what should have been done instead.

Answer with Premium
Examiner's tip · PremiumUnlock
P2

Measuring and recording

Select apparatus for an investigation, read it correctly, and record the readings so that they can be used.

Key points

  • The syllabus names the apparatus you may be asked about: MEASURING CYLINDERS (10, 25 and 100 cm cubed), SYRINGES (1, 5 and 10 cm cubed), THERMOMETERS (−10 to +110 degrees C in 1 degree C steps), STOP-CLOCKS (1 s or better), a BALANCE to 0.1 g, mm RULERS and HAND LENSES of at least times 6.
  • Reading apparatus is the single commonest question type in the bank for this paper, and the marks are lost on two things only: the UNIT and the EYE POSITION.
  • Always record the unit with the number, and always take it from the scale rather than from memory: a 100 cm cubed cylinder graduated every 1 cm cubed cannot give 28.5.
  • RAW readings go in the table exactly as the instrument gives them, to the SAME number of decimal places down the column. Processed values (means, changes, rates) go in their own column with their own heading and unit.
  • Every table column needs a HEADING WITH A UNIT, written as 'quantity / unit' — 'time / s', 'mass / g', 'volume of gas / cm cubed'.
  • Choose the instrument by RANGE first (it must reach the largest value) and RESOLUTION second (its smallest division must be small enough to show the differences you care about).
  • REPEAT every reading at least three times under identical conditions so that a mean can be taken and an odd value can be spotted.
  • Record what you SEE, not what you expect. A colour that is between two standards is recorded as between them, not rounded to the one you wanted.

Worked example

3 marks

A student must measure out 8 cm cubed of amylase solution and time a reaction that lasts about half a minute. State which piece of apparatus should be used for each, and give a reason for each choice.

Answer with Premium
Examiner's tip · PremiumUnlock
P3.1

Means, and when to leave a reading out

Calculate the mean and range of a set of repeated readings, and decide which readings belong in the mean.

Key points

  • MEAN = the total of the readings divided by HOW MANY readings there are. It is the only average the syllabus asks for.
  • RANGE = largest reading minus smallest. The range measures SPREAD and tells you how much the repeats disagree; it is not an average.
  • Quote the mean to the same number of decimal places as the readings, or ONE MORE. Three whole-second readings give a mean such as 26.3 s, not 26.333333 s.
  • Taking a mean reduces the effect of RANDOM error, because readings that are too high and too low partly cancel.
  • Leave an ANOMALOUS reading OUT of the mean, and say that you have done so. Divide by the number of readings you actually used, not by the original number.
  • A mean of readings that disagree badly can describe a value NOBODY measured: 72, 75 and 40 per cent give a mean of 62 per cent, lower than two of the three results.
  • Three repeats is the usual minimum. With only two you cannot tell which of a disagreeing pair is the odd one.

Worked example

3 marks

Three students each repeated the same germination experiment under identical conditions and obtained germination percentages of 72 per cent, 75 per cent and 40 per cent. Explain how the 40 per cent result should be treated, and why a mean of all three would be misleading.

Answer with Premium
Examiner's tip · PremiumUnlock
P3.4

Choosing scales, plotting points and drawing the line

Choose scales for a graph, plot the points accurately and draw the line or curve the results call for.

Key points

  • Independent variable on the X AXIS, dependent variable on the Y AXIS, both labelled 'quantity / unit'.
  • Choose scales so that the plotted points occupy MORE THAN HALF the grid in BOTH directions. A graph crammed into one corner loses the scale mark however well the points are plotted.
  • Use 1, 2, 5 or 10 units per large square. Scales of 3, 4, 7 or 9 units per square make every point a guess and are marked wrong.
  • Scales do not have to start at zero unless the question asks for an intercept. Starting at 20 degrees C when the lowest reading is 20 degrees C is good practice, not a fault.
  • Plot each point with a sharp pencil as a small CROSS or an encircled dot, to within half a small square.
  • Draw a STRAIGHT line of best fit when the points lie on a straight line, with roughly as many points above it as below. Do NOT force it through the origin unless the data go there.
  • Draw a SMOOTH CURVE when the points lie on a curve — a single continuous line drawn through the trend, not a dot-to-dot zigzag and not two straight lines meeting at a corner.
  • Ignore an anomalous point when drawing the line, but leave the point on the graph and ring it.

Worked example

4 marks

A student measured the rate at which catalase decomposed hydrogen peroxide at six temperatures. The readings were: 10 degrees C, 1.2 cm cubed per min; 20 degrees C, 2.8; 30 degrees C, 4.6; 40 degrees C, 5.4; 50 degrees C, 3.0; 60 degrees C, 0.6. Describe the graph you would draw, and state what kind of line it needs.

Answer with Premium
Examiner's tip · PremiumUnlock
P3.5

Reading values from a graph, and describing its shape

Read a value from a graph showing your construction lines, and describe and explain the shape of a curve.

Key points

  • To read a value, draw CONSTRUCTION LINES: up from the x axis to the line, then across to the y axis, both drawn with a ruler and left on the graph. The construction lines are usually worth a mark on their own.
  • Read from YOUR OWN line of best fit, not from the nearest plotted point, and give the answer WITH ITS UNIT.
  • INTERPOLATION is reading a value BETWEEN the points you measured and is reliable. EXTRAPOLATION continues the line beyond them and is not, because the relationship may change.
  • Describe a graph in two steps: the DIRECTION of the trend, then WHERE it changes. 'The rate rises steeply up to 30 units, then levels off at 60 bubbles per minute above 40 units.'
  • Quote NUMBERS WITH UNITS from the axes when describing a shape. 'It goes up then flattens' earns nothing on its own.
  • A PLATEAU means something else has become the LIMITING FACTOR. Only one factor can be limiting at a time, so name the factor that was in shortest supply.
  • A PEAK followed by a steep fall is the enzyme signature: the rise is more kinetic energy and more effective collisions, the fall is DENATURATION, and the fall is steeper because denaturation does not reverse on cooling.
  • A GRADIENT is taken from a LARGE triangle on the line, as change in y divided by change in x, with the unit of y per the unit of x.

Worked example

4 marks

A student plotted the volume of oxygen released in one minute against enzyme concentration and obtained a straight line through the origin passing through (1, 5.0) and (5, 25.0), where concentration is in arbitrary units and volume in cm cubed. Find the gradient, and use the line to find the volume at a concentration of 3.5 units.

Answer with Premium
Examiner's tip · PremiumUnlock
P5

Errors, anomalies and improvements

Identify anomalous results and sources of error, and suggest specific improvements to a method.

Key points

  • An ANOMALOUS result is one that does not fit the pattern of the others — a value well outside the spread of the repeats at the same conditions.
  • What to do with one: REPEAT the reading if you can, and leave it OUT of the mean if you cannot. Never quietly average it in, and never delete it from the table.
  • RANDOM error varies unpredictably from reading to reading and makes results SCATTER. It is reduced by REPEATING and taking a MEAN.
  • SYSTEMATIC error shifts every reading the SAME way by the SAME amount — a balance not zeroed, a leaking joint, a thermometer reading 2 degrees C high. Repeating does NOT reduce it; it has to be found and corrected.
  • PARALLAX is reading a scale from an angle instead of straight on. It is cured by putting the eye LEVEL with the mark, and by laying a ruler flat against the object instead of holding it above.
  • RELIABLE means the repeats agree with each other; ACCURATE means the readings are close to the true value. Repeating improves reliability and tells you nothing about accuracy.
  • An improvement earns a mark only if it is SPECIFIC and could actually be done: 'use a thermostatically controlled water bath' not 'control the temperature'; 'collect the gas in a 10 cm cubed syringe' not 'be more accurate'.
  • A conclusion is only supported if the readings show a clear difference that is LARGER THAN THE SPREAD of the repeats, and if no other variable changed alongside the independent variable.

Worked example

3 marks

A student timed how long starch solution took to be fully digested by amylase, repeating the measurement five times under identical conditions. The times recorded were 22 s, 9 s, 19 s, 20 s and 21 s. Identify the anomalous result, state what should be done with it, and suggest one cause.

Answer with Premium
Examiner's tip · PremiumUnlock
P5.1

Anomalous results

Identify an anomalous result, say what should be done with it, and suggest a cause.

Key points

  • An ANOMALOUS result does not fit the pattern of the rest — it lies well OUTSIDE the spread of the other repeats taken under the same conditions.
  • Compare it with the OTHER REPEATS, not with what you expected. Four readings between 95 s and 110 s make a fifth reading of 40 s anomalous; a reading of 97 s is not.
  • What to do: REPEAT the reading. If it cannot be repeated, EXCLUDE it from the mean and say so. Leave it in the TABLE and ring it; do not erase it.
  • On a graph, plot the anomalous point, ring it, and IGNORE it when drawing the line of best fit.
  • Suggest a SPECIFIC cause: the stop-clock started late, the specimen was cut to the wrong size, the tube had not reached the temperature of the bath, a joint leaked, a solution was made up at the wrong concentration.
  • An anomaly caused by a MISTAKE in one run is random; if EVERY reading is out the same way the fault is systematic and excluding one reading will not fix it.
  • A set of readings with a wide RANGE has no single anomaly — it has poor precision, and the answer is to repeat the whole set with the method tightened.

Worked example

3 marks

A student timed how long five potato cylinders took to sink in sucrose solution. One result was 40 s when the other four were between 95 s and 110 s. Suggest why this result is anomalous, state what should be done about it, and say how the mean should then be calculated.

Answer with Premium
Examiner's tip · PremiumUnlock
P6.3

Enzyme activity against temperature and pH

Describe and evaluate an investigation into the effect of temperature or pH on enzyme activity.

Key points

  • AMYLASE AND STARCH: stand equal volumes of starch solution and amylase in SEPARATE tubes in the water bath until both reach its temperature, then mix and start the stop-clock.
  • At regular intervals take a drop out with a dropping pipette and test it with IODINE on a white tile. Record the time at which the iodine NO LONGER turns blue-black — that is the end point.
  • CATALASE AND HYDROGEN PEROXIDE: add the enzyme to hydrogen peroxide and collect the OXYGEN in a gas syringe, recording the volume collected in a fixed time.
  • Rate = 1 DIVIDED BY THE TIME for the iodine method, or VOLUME DIVIDED BY TIME for the gas method. Plot the rate, not the time, so the curve comes out the right way up.
  • For TEMPERATURE use at least five values across a wide range, such as 20, 30, 40, 50 and 60 degrees C, in a thermostatically controlled water bath. The curve rises to an OPTIMUM and then falls STEEPLY.
  • For pH use BUFFER SOLUTIONS to fix the pH, with the temperature held constant, and at least five pH values. Keep the volume of buffer the same in every tube.
  • Control the VOLUME and CONCENTRATION of enzyme and substrate, the volume of buffer, and the drop size and timing interval of the iodine testing.
  • A CONTROL of BOILED enzyme shows that the starch is broken down by the enzyme and not by the heat, the buffer or the water.

Worked example

5 marks

Describe how you would investigate the effect of temperature on the activity of the enzyme amylase. State the measurements you would take and how you would make it a fair test.

Answer with Premium
Examiner's tip · PremiumUnlock

Exam-style questions

Answer the multiple-choice questions free, then see what Premium does with written answers. These are 5 of the 140 questions on this topic in IGXEED.

  1. Question 11 markCore

    Enzymes are important in living organisms because they:

    1. ASpeed up chemical reactions, allowing life processes to occur at a suitable rate
    2. BAre used up during every reaction they catalyse, so a fresh supply must be made each time
    3. COnly work outside the body, which is why they are used in washing powders and food processing
    4. DSlow down the chemical reactions in a cell so that they do not release their heat too quickly
    Show the answer

    Answer: A. Speed up chemical reactions, allowing life processes to occur at a suitable rate

  2. Question 21 markCore

    Which of the following would most likely denature an enzyme?

    1. ASlightly raising the substrate concentration
    2. BAdding more water
    3. CSlightly lowering the temperature
    4. DBoiling the enzyme solution
    Show the answer

    Answer: D. Boiling the enzyme solution

  3. Question 31 markCore

    Starch digestion begins in the mouth but stops in the stomach. What is the reason for this?

    1. AThe starch does not remain in the stomach long enough to be digested
    2. BAll starch digestion is completed in the mouth before reaching the stomach
    3. CThe stomach temperature is too low for amylase to work
    4. DThe low pH of the stomach denatures amylase so it cannot function
    Show the answer

    Answer: D. The low pH of the stomach denatures amylase so it cannot function

  4. Question 44 marksCore Premium

    Describe how you could investigate the effect of enzyme concentration on the rate of an enzyme-catalysed reaction.

    Free accounts get 3 written answers a day marked by AI. Premium marks every written and sketch question like this one against the mark scheme in seconds, so you see exactly which points you earned and which you missed.

    Unlock every question type
  5. Question 54 marksCore Premium

    Describe an experiment to investigate the effect of temperature on the rate of an enzyme-catalysed reaction, using catalase and hydrogen peroxide.

    Free accounts get 3 written answers a day marked by AI. Premium marks every written and sketch question like this one against the mark scheme in seconds, so you see exactly which points you earned and which you missed.

    Unlock every question type

Practise all 140 questions on Enzymes

Multiple-choice practice is free, 20 questions a day and up to 50 a week, plus 3 written answers a day marked by AI. Premium marks every written and sketch answer against the mark scheme, so you see exactly which points you missed, and opens the full notes.